Tahanan ( R ) dan reaktansi ( XL ) penghantar AAC tegangan 20 kV
(SPLN 64: 1985)
Luas Penampang mm2
|
Jari2mm
|
Urat
|
GMR (mm)
|
Impedansi urutan positif (Ohm / km)
|
Impedansi urutan Nol (Ohm / km)
|
16
|
2,2563
|
7
|
1,6380
|
1,8382 + j 0,4035
|
1,9862 + j 1,6910
|
25
|
2,8203
|
7
|
2,0475
|
1,1755 + j 0,3895
|
1,3245 + j 1,6770
|
35
|
3,3371
|
7
|
2,4227
|
0,8403 + j 0,3791
|
0,9883 + j 1,6666
|
50
|
3,9886
|
7
|
2,8957
|
0,5882 + j 0,3677
|
0,7362 + j 1,6552
|
70
|
4,7193
|
7
|
3,4262
|
0,4202 + j 0,3572
|
0,5682 + j 1,6447
|
95
|
5,4979
|
19
|
4,1674
|
0,3096 + j 0,3464
|
0,4576 + j 1,6339
|
120
|
6,1791
|
19
|
4,6837
|
0,2451 + j 0,3375
|
0,3931 + j 1,6250
|
150
|
6,9084
|
19
|
5,2365
|
0,1961 + j 0,3305
|
0,3441 + j 1,6180
|
185
|
7,6722
|
19
|
5,8155
|
0,1590 + j 0,3239
|
0,3070 + j 1,6114
|
240
|
8,7386
|
19
|
6,6238
|
0,1225 + j 0,3157
|
0,2705 + j 1,6032
|
Tahanan ( R ) dan reaktansi ( XL ) penghantar AAAC tegangan 20 kV
(SPLN 64: 1985)
(SPLN 64: 1985)
Luas Penampang (mm2)
|
Jari2mm
|
Urat
|
GMR (mm)
|
Impedansi urutan positif (Ohm / km)
|
Impedansi urutan Nol (Ohm / km)
|
16
|
2,2563
|
7
|
1,6380
|
2,0161 + j 0,4036
|
2,1641 + j 1,6911
|
25
|
2,8203
|
7
|
2,0475
|
1,2903 + j 0,3895
|
1,4384 + j 1,6770
|
35
|
3,3371
|
7
|
2,4227
|
0,9217 + j 0,3790
|
1,0697 + j 1,6665
|
50
|
3,9886
|
7
|
2,8957
|
0,6452 + j 0,3678
|
0,7932 + j 1,6553
|
70
|
4,7193
|
7
|
3,4262
|
0,4608 + j 03572
|
0,6088 + j 1,6447
|
95
|
5,4979
|
19
|
4,1674
|
0,3096 + j 0,3449
|
0,4876 + j 1,6324
|
120
|
6,1791
|
19
|
4,6837
|
0,2688 + j 0,3376
|
0,4168 + j 1,6324
|
150
|
6,9084
|
19
|
5,2365
|
0,2162 + j 0,3305
|
0,3631 + j 1,6180
|
185
|
7,6722
|
19
|
5,8155
|
0,1744 + j 0,3239
|
0,3224 + j 1,6114
|
240
|
8,7386
|
19
|
6,6238
|
0,1344 + j 0,3158
|
0,2824 + j 1,6034
|
Tahanan, induktansi dan kapasitansi kabel isolasi XLPE:
N2XSEKBY/NA2XSEKBY tegangan 12 / 20 kV.
(IEC. 502)
N2XSEKBY/NA2XSEKBY tegangan 12 / 20 kV.
(IEC. 502)
∑ peng hantar
|
Penghantar
|
Tahanan maks pada DC temp 200C
|
Tahanan pada AC temp 900C
|
saat operasi
|
Maks kapasitas arus temp 300C
|
Arus hub singkat selama 1 detik
|
Teg nom. prcbn
| |||
Luas pnmpg
|
Cu /Al
|
Induktansi (L)
|
Kapasitansi (C)
|
dlm tanah
|
di udara
| |||||
mm2
|
Ohm/km
|
Ohm/km
|
mH/km
|
mF/km
|
Amp
|
Amp
|
kA
| kV/5 min | ||
3
|
35
|
CU
|
0,5240
|
0,6680
|
0,520
|
0,131
|
164
|
173
|
5,01
|
30
|
Al
|
0,8680
|
1,1130
|
0,520
|
0,131
|
127
|
139
|
3,29
|
30
| ||
3
|
50
|
Cu
|
0,3870
|
0,4940
|
0,497
|
0,143
|
194
|
206
|
7,15
|
30
|
Al
|
0,6410
|
0,8220
|
0,497
|
0,143
|
148
|
161
|
4,70
|
30
| ||
3
|
70
|
Cu
|
0,2680
|
0,3420
|
0,467
|
0,162
|
236
|
257
|
10,01
|
30
|
Al
|
0,4430
|
0,5680
|
0,467
|
0,162
|
179
|
204
|
6,58
|
30
| ||
3
|
95
|
Cu
|
0,1930
|
0,2470
|
0,445
|
0,180
|
283
|
313
|
13,59
|
30
|
Al
|
0,3200
|
0,4110
|
0,445
|
0,180
|
214
|
242
|
8,93
|
30
| ||
3
|
120
|
Cu
|
0,1530
|
0,1960
|
0,430
|
0,195
|
322
|
360
|
17,16
|
30
|
Al
|
0,2530
|
0,3250
|
0,430
|
0,195
|
246
|
292
|
11,28
|
30
| ||
3
|
150
|
Cu
|
0,1240
|
0,1590
|
0,414
|
0,213
|
362
|
410
|
21,45
|
30
|
Al
|
0,2060
|
0,2650
|
0,414
|
0,213
|
264
|
313
|
14,10
|
30
| ||
3
|
185
|
Cu
|
0,0991
|
0,1280
|
0,404
|
0,227
|
409
|
469
|
26,46
|
30
|
Al
|
0,1640
|
0,2110
|
0,404
|
0,227
|
308
|
365
|
17,39
|
30
| ||
3
|
240
|
Cu
|
0,0754
|
0,0980
|
0,382
|
0,263
|
474
|
553
|
34,32
|
30
|
Al
|
0,1250
|
0,1620
|
0,382
|
0,273
|
358
|
425
|
22,56
|
30
| ||
3
|
300
|
Cu
|
0,0601
|
0,0790
|
0,376
|
0,276
|
533
|
629
|
42,90
|
30
|
Al
|
0,1000
|
0,1300
|
0,376
|
0,276
|
398
|
481
|
28,20
|
30
| ||
Impedansi Kabel Tanah Dengan Penghantar Al
A
(mm2)
|
R
(Ω/km)
|
L
(mH/km)
|
C
(mf/km)
|
Impedansi urutan positif
(Ω /km)
|
Impedansi urutan Nol
(Ω/km)
|
150
|
0,206
|
0,33
|
0,26
|
0,206 + j 0,104
|
0,356 + j 0,312
|
240
|
0,125
|
0,31
|
0,31
|
0,125 + j0,097
|
0,275 +j0,029
|
300
|
0,100
|
0,30
|
0,34
|
0,100 + j0,094
|
0,250 + j0,282
|